ASTM F2458 Wound Closure Strength of Tissue Adhesives and Sealants

Mechanical Testing of Bioadhesives

ASTM F2458

ASTM F2458 is a testing standard that specifically focuses on characterizing the wound closure strength of tissue adhesives or sealants. Adhesive wound closure is sometimes preferable to using staples or stitches, as it reduces patient discomfort is and is often more easy to apply. It is extremely important that these products perform as expected, as failure could cause internal or external bleeding and leave a patient vulnerable to infection at the wound site. In order for wounds to heal properly over time and prevent scarring, the adhesive must continue to hold the tissue together until healing occurs.

ASTM F2458 is primarily intended for comparative testing between different adhesive formulations. Identifying a repeatable and life-like substrate enables this standard to be used for quality control purposes of adhesive wound closure products. The test will provide the maximum force at the time of failure as well as the failure mode – typically labelled as adhesive (failure of the adhesive/substrate bond), cohesive (failure of the internal adhesive bond), or substrate failure (failure of the tissue). To read the standard in full, purchase ASTM F2458.

Materials Testing System

For ASTM F2458 testing we recommend a 6800 Series single column testing system with a 100 N load cell and pneumatic grips. Because tissues are typically fragile, they require surfalloy style faces for clamping on the specimen successfully. A flexible coupling is required to ensure the loading is applied through the center of the specimen. For closure devices used internally within the body, the testing should be performed at a temperature of 37 Celsius. A biobox is useful for testing at body temperature.

ASTM F2458 Test Setup
1) 5900 Series Universal Testing System
2) 2530-100 Load Cell
3) Pneumatic Side Action Grips
4) Instron BioBox

 

ASTM F2458 system setup
Related Content

最高クラスの6800シリーズ試験機のカタログ

インストロン6800シリーズ万能材料試験機は、他に類のない精度と信頼性を提供します。特許申請中のオペレーター保護機能に基づき、最新のスマートクローズエアキットおよび衝突緩和機能を搭載した6800シリーズは、材料試験をかつてないほどシンプルに、スマートに、安全にします。

Bluehill Universalのカタログ

Bluehill Universalソフトウェアは、タッチ操作と直感的なユーザーエクスペリエンスを念頭に構築されています。標準装備の試験メソッド、数秒で行われるQuickTest、強化されたデータエクスポート、そしてサービスとの直接通信を提供する新機能Instron Connectなどの機能が、これまでよりもシンプルでスマートな試験を可能にします。Bluehill 2やBluehill 3などの旧バージョンソフトウェアからは、簡単に最新バージョンのBluehillにアップグレードできます。

37℃医療機器試験用のBioBox

インストロンのBioBoxは、体温と同じくらいの温度(37℃)に調整された空気環境を提供できるため、医療機器および生体材料の試験が大変行いやすい製品です。

液槽内で使用可能な空気圧式サイドアクショングリップおよび温度制御可能なBioBath

インストロンの温度制御可能なBioBathを使用すると、医療製品分野の試験で要求される環境条件を正確にシミュレートできます。